Description
The eFlow104NA8D serves as a power distribution and switching solution for access control systems and accessories. It transforms a 120VAC 60Hz input into eight (8) independently controlled 24VDC outputs with PTC protection. These outputs can be configured to function as dry form “C” contacts. They are activated by an open collector sink or normally open (NO) dry trigger input from devices like Access Control Systems, Card Readers, Keypads, Push Buttons, PIR sensors, and more. This unit efficiently supplies power to various access control hardware, including Magnetic Locks, Electric Strikes, Magnetic Door Holders, and similar devices, supporting both Fail-Safe and Fail-Secure operations. The integrated FACP Interface facilitates Emergency Egress, Alarm Monitoring, and the triggering of auxiliary devices. Additionally, the fire alarm disconnect feature can be selectively applied to any or all of the eight (8) outputs.