Description

The MRP-2002 is a six-zone Fire Alarm Control Panel (FACP) designed for single and dual hazard agent releasing applications. It ensures dependable fire detection, signaling, and protection for commercial, industrial, and institutional facilities that require agent-based releasing. This FACP is compatible with System Sensor’s i3 conventional smoke detectors, which can communicate maintenance trouble signals to the panel, indicating a need for cleaning, as well as a supervisory ‘freeze’ alert when temperatures drop below 45°F (7.22°C). Furthermore, the control panel supports conventional input devices, including two-wire and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. For a comprehensive list of compatible devices, refer to the FireLite Device Compatibility Document. The panel includes four outputs that can be programmed as Notification Appliance Circuits (NACs) or releasing circuits. It also comes with three Form-C relays pre-programmed for Alarm, Trouble, and Supervisory functions, as well as 24 VDC special application resettable and non-resettable power outputs on the main circuit board. The MRP-2002 supervises all wiring, AC voltage, battery charger, and battery levels. When a compatible smoke detector or any normally-open fire alarm initiating device is activated, it triggers audible and visual signaling devices, lights up an indicator, displays alarm information on the control panel’s LCD, sounds the piezo sounder, activates the FACP alarm relay, and operates an optional module to notify a remote station or initiate an auxiliary control function. The MRP-2002E variant provides similar features but supports connection to 220/240 VAC. Unless specified otherwise, the details in this data sheet are applicable to both the 110/120 VAC and 220/240 VAC versions of the panels.

Battery Information
Battery Built-inYes
 
Display & Graphics
Display TypeLCD
 
General Information
Brand NameFire-Lite Alarms by Honeywell
ManufacturerHoneywell International, Inc
Manufacturer Part NumberMRP2002
Product LineMRP
Product ModelMRP-2002
Product NameMRP-2002 Fire Alarm Control Panel
Product SeriesMRP
Product TypeFire Alarm Control Panel
 
Miscellaneous
CompatibilitySystem Sensor i3 Series DetectorsFire-Lite:Smoke DetectorsPull StationsWaterflow DevicesTamper Switches
Features24 volt operation, 7.0 amps total 24 VDC output current, ANN-BUS connector for communication with optional devices 80-character LCD display (backlit) Real-time clock/calendar with daylight savings time control, Automatic battery charger with charger supervision, Built-in Programmer, Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001, Extensive transient protection Dual hazard operation Adjustable pre-discharge, discharge and waterflow delay timers Cross-zone (double-interlock) capability, FM Approved, Four programmable Style Y (Class B) output circuits - (special application power), History log with 256 event storage, Listed to UL Standard 864, 9th edition, Low AC voltage sense, Meets International Building Code (IBC) seismic requirements Disable/Enable control per input zone and output zone, Piezo sounder for alarm, trouble and supervisory, Resettable and non-resettable output power, Six programmable Style B (Class B) IDCs (Initiating Device Circuit) System Sensor i3 series detector compatible, Strobe synchronization, Three programmable Form-C relays
Package ContentsMRP-2002 Fire Alarm Control PanelBackboxPower SupplyTechnical ManualInstruction Sheet
 
Physical Characteristics
Application/UsageCommercial
 
Power Description
Input Voltage120V AC
 
Technical Information
Maximum Number of Zones Supported6
Number of Events Log256
Number of Standard Zones6
Panel Control TypeConventional
 
Warranty
Limited Warranty3 Year

Customer Reviews

No reviews yet.

Recently Viewed